24-ICM2801

OEM Replacement, York/Evcon 7990-319P

Controls vent motor, blower control, hot surface ignitor and gas valve. Monitors timing, trial for ignition, flame sensing and lockout. Microprocessor-based. Reverse polarity protection 100% lockout safety feature. Compatible with LP or natural gas Status LED for fault codes to aid in troubleshooting. Twinning compatible with another ICM2801 control.

Line Voltage: 98-132 VAC @ 60HZ | Ignitor: 5A,120 VAC | Cool Blower: 10A, 2HP, 240 VAC | Heat: 5A, .5 HP, 250 VAC | Inducer Blower: 4A, 120 VAC | Gas Valve: 1A, 24 VAC.

 

Additional information

Cross Reference

7990319P

HS Code Country Of Origin NAFTA Preference Criterion NAFTA Producer Index
0__